{
  "eventId": "GRB 260207B",
  "bibcode": "2026GCN.43634....1S",
  "circularId": 43634,
  "createdOn": 1770524677386,
  "subject": "GRB 260207B: Fermi GBM Detection of a Short Burst with Extended Emission",
  "submitter": "Rushikesh Sonawane  at IISER, TVM <rushikesh23@iisertvm.ac.in>",
  "body": "R. Sonawane (IISER, TVM) and S. Bala (USRA) report on behalf of\nthe Fermi Gamma-ray Burst Monitor Team:\n\n\"At 13:12:10.83 UT on 07 February 2026, the Fermi Gamma-ray Burst Monitor (GBM)\ntriggered and located GRB 260207B (trigger 792162735/260207550).\n\nThe on-ground calculated location, using the Fermi GBM trigger data,\nis RA = 292.87, Dec = 50.03 (J2000 degrees, equivalent to\nJ2000 19h 31m, +50d 1'), with a statistical uncertainty of 2.81 degrees.\n(radius, 1-sigma containment, statistical only; there is additionally a\nsystematic error which we have characterized as a mixture of two Gaussians,\none with a radius of 1.8 degrees (52% contribution) and one with a radius\nof 4.1 degrees (47% contribution) [A. Goldstein et al. 2020, ApJ, 895, 1]).\n\nThe angle from the Fermi LAT boresight is 45 degrees.\n\nThe GBM light curve consists of a short spike (Main Emission, ME) \nfollowed by an extended emission (EE) with a total duration (T90) of about 56 s (50-300 keV).\n\nThe ME from T0-1 to T0+5 s is best fit by a power law function with an \nexponential high-energy cutoff. The power law index is -1.18 +/- 0.07 and the\ncutoff energy, parameterized as Epeak, is 350 +/- 65 keV. The total fluence (10-1000 keV) \nin this time interval is (2.7 +/- 0.1)E-06 erg/cm^2.\n\nThe EE from T0+10 to T0+89 s, is best fit by a Band function with \nEpeak= 32 +/- 4 keV, alpha = -1.7 +/- 0.1 and beta = -2.4 +/- 0.1. \nThe total fluence (10-1000 keV) during this time interval is (7.5 +/- 0.4)E-06 erg/cm^2. \n\n\nThe time-averaged (ME+EE) spectrum from T0-2 to T0+89 s is best fit by\na power law function with an exponential high-energy cutoff.\nThe power law index is -1.83 +/- 0.05 and the cutoff energy,\nparameterized as Epeak, is 67 +/- 9 keV. A Band function fits this interval equally\nwell with Epeak= 52 +/- 10 keV,  alpha = -1.7 +/- 0.1 and beta = -2.2 +/- 0.1. \nThe event fluence (10-1000 keV) in this time interval is (9.6 +/- 0.5)E-06 erg/cm^2. \nThe 1-sec peak photon flux measured starting from T0+0.0024 s in the 10-1000 keV band\nis 16.6 +/- 0.3 ph/s/cm^2.\n\n\nThe spectral analysis results presented above are preliminary;\nfinal results will be published in the GBM GRB Catalog:\nhttps://heasarc.gsfc.nasa.gov/W3Browse/fermi/fermigbrst.html\n\nFor Fermi GBM data and info, please visit the official Fermi GBM Support Page:\nhttps://fermi.gsfc.nasa.gov/ssc/data/access/gbm/\"",
  "submittedHow": "web",
  "format": "text/plain"
}