report on the behalf of the Swift UVOT team:

In the GCN circ 11095 (Swift/UVOT observations of
GRB100814A) the table containing the information
on epochs and magnitudes could not be read well because
of a formatting problem. In the following, we rewrite
the table with a clearer look.

  We apologize for any inconvenience it might have caused.


Filter      T_start   T_stop    Exp(s)      Mag   Err
----------------------------------------------------------
    u (fc)    153      403        246      16.80  0.06
    v         458      627        39       17.91  0.32
    b         408      721        53       21.22  0.20
    u         153      701       285       16.84  0.06
  uvw1        507      676        39       17.33  0.20
  uvm2        483      651        39       17.86  0.31
  uvw2        434      602        39      >18.52  3-sigma UL
  white      3858     4211       344       18.63  0.07
----------------------------------------------------------


[GCN OPS NOTE(15aug10):  Per author's request, the "B" 
in the Subject line was changed to "A".]