Skip to main content
New Announcement Feature, Code of Conduct, Circular Revisions. See news and announcements

GCN Circular 11819

Subject
GRB 101225A: revised analysis of narrow band imaging
Date
2011-03-22T19:16:23Z (13 years ago)
From
Nial Tanvir at U.Leicester <nrt3@star.le.ac.uk>
N. R. Tanvir (U. Leicester) and A. J. Levan (U. Warwick) report:

We have re-reduced and re-analysed more thoroughly the imaging reported
in GCN 11642. While it remains the case that the optical transient is
detected in the H-alpha narrow-band filter, and at best marginally present
in the r-band, the significance of the excess H-alpha detection is reduced.��
Within the associated errors the revised photometry is broadly consistent
with the red colour of the transient at this time (the narrow-band filter being
somewhat redward of the central wavelength of the r-band filter), and hence,
the data do not require significant line emission. This argument for a z~0
origin is therefore weakened.
Looking for U.S. government information and services? Visit USA.gov