GCN Circular 16087
Subject
GRB 140408A: Swift-XRT refined Analysis
Date
2014-04-09T04:36:03Z (10 years ago)
From
Phil Evans at U of Leicester <pae9@leicester.ac.uk>
J.A. Kennea (PSU), V. Mangano (PSU), M.C. Stroh (PSU), B.P. Gompertz
(U. Leicester), J.P. Osborne (U. Leicester), K.L. Page (U. Leicester),
A. Maselli (INAF-IASFPA), A. Melandri (INAF-OAB) and V. D'Elia report
on behalf of the Swift-XRT team:
We have analysed 8.7 ks of XRT data for GRB 140408A (D'Elia et al. GCN
Circ. 16082), from 91 s to 29.8 ks after the BAT trigger. The data
comprise 268 s in Windowed Timing (WT) mode (the first 8 s were taken
while Swift was slewing) with the remainder in Photon Counting (PC)
mode. The enhanced XRT position for this burst was given by Evans et
al. (GCN Circ. 16085).
The light curve can be modelled with a power-law decay with a decay
index of alpha=0.77 (+0.10, -0.09).
A spectrum formed from the WT mode data can be fitted with an absorbed
power-law with a photon spectral index of 2 (+80, -1). The
best-fitting absorption column is 1.4 (+7.3, -1.2) x 10^22 cm^-2,
consistent with the Galactic value of 1.8 x 10^21 cm^-2 (Willingale et
al. 2013). The counts to observed (unabsorbed) 0.3-10 keV flux
conversion factor deduced from this spectrum is 1.5 x 10^-11 (6.9 x
10^-11) erg cm^-2 count^-1.
A summary of the WT-mode spectrum is thus:
Total column: 1.4 (+7.3, -1.2) x 10^22 cm^-2
Galactic foreground: 1.8 x 10^21 cm^-2
Excess significance: <1.6 sigma
Photon index: 2 (+80, -1)
If the light curve continues to decay with a power-law decay index of
0.77, the count rate at T+24 hours will be 2.1 x 10^-3 count s^-1,
corresponding to an observed (unabsorbed) 0.3-10 keV flux of 3.1 x
10^-14 (1.5 x 10^-13) erg cm^-2 s^-1.
The results of the XRT-team automatic analysis are available at
http://www.swift.ac.uk/xrt_products/00595141.
This circular is an official product of the Swift-XRT team.