Skip to main content
New! Circulars over Kafka, Heartbeat Topic, and Schema v4.1.0. See news and announcements

GCN Circular 17781

Subject
GRB 150428B: Swift-XRT refined Analysis
Date
2015-04-28T15:37:03Z (9 years ago)
From
Phil Evans at U of Leicester <pae9@leicester.ac.uk>
P. D'Avanzo (INAF-OAB), V. D'Elia (ASDC), J.A. Kennea (PSU), B.
Sbarufatti (INAF-OAB/PSU), D.N. Burrows (PSU), P.A. Evans (U.
Leicester), A. Amaral-Rogers (U. Leicester), J.P. Osborne (U.
Leicester), M. de Pasquale (INAF-IASFPA) and K.L. Page report on behalf
of the Swift-XRT team:

We have analysed 8.3 ks of XRT data for GRB 150428B (Page et al. GCN
Circ. 17766), from 100 s to 34.4 ks after the  BAT trigger. The data
comprise 187 s in Windowed Timing (WT) mode (the first 6 s were taken
while Swift was slewing) with the remainder in Photon Counting (PC)
mode. The enhanced XRT position for this burst was given by Beardmore
et al. (GCN Circ. 17773).

The light curve can be modelled with a series of power-law decays. The
initial decay index is alpha=2.31 (+0.16, -0.20). At T+170 s  the decay
steepens to an alpha of 4.92 (+0.15, -0.16) before breaking again at
T+618 s to a final decay with index alpha=0.29 (+/-0.07).

A spectrum formed from the WT mode data can be fitted with an absorbed
power-law with a photon spectral index	of 1.93 (+0.06, -0.05). The
best-fitting absorption column is  3.51 (+0.28, -0.25) x 10^21 cm^-2,
consistent with the Galactic value of 3.3 x 10^21 cm^-2 (Willingale et
al. 2013). The PC mode spectrum has a photon index of 1.90 (+0.16,
-0.08) and a best-fitting absorption column consistent with the
Galactic value. The counts to observed (unabsorbed) 0.3-10 keV flux
conversion factor deduced from this spectrum  is 3.9 x 10^-11 (5.6 x
10^-11) erg cm^-2 count^-1. 

A summary of the PC-mode spectrum is thus:
Total column:	     3.3 (+0.3, -0.0) x 10^21 cm^-2
Galactic foreground: 3.3 x 10^21 cm^-2
Excess significance: <1.6 sigma
Photon index:	     1.90 (+0.16, -0.08)

If the light curve continues to decay with a power-law decay index of
0.29, the count rate at T+24 hours will be 0.027 count s^-1,
corresponding to an observed (unabsorbed) 0.3-10 keV flux of 1.1 x
10^-12 (1.5 x 10^-12) erg cm^-2 s^-1.

The results of the XRT-team automatic analysis are available at
http://www.swift.ac.uk/xrt_products/00639278.

This circular is an official product of the Swift-XRT team.
Looking for U.S. government information and services? Visit USA.gov