Skip to main content
New Announcement Feature, Code of Conduct, Circular Revisions. See news and announcements

GCN Circular 23629

Subject
GRB 190106A: update of the Xinglong-2.16m spectroscopy
Date
2019-01-07T05:25:15Z (5 years ago)
From
Dong Xu at NAOC/CAS <dxu@nao.cas.cn>
D. Xu, Z.P. Zhu, Y. Wang, J.B. Zhang (NAOC), J.H. Liu, X. Zhang (XAO) 
report:

We have re-reduced the 3600s+3000s spectra taken from the Xinglong-2.16m 
telescope (Zhu et al., GCN 23623), with the calibration frames taken in 
the same night. The Signal-to-Noise of the spectrum increased compared 
with the previous 3600s one, and the resolution is not high due to 
seeing~2.0".

We only consider relatively prominent absorption features and thus only 
six features are left, which can be interpreted as C IV 1547.62, 1550.19,
Fe II 2585.88, 2599.40, and Mg II doublet 2795.53, 2802.71
(wavelength in air), at an updated and consistent redshift of z=1.86.

[GCN OPS NOTE(08jan19): Per author's request, In the SUBJECT-line,
the "180106A" was changed to "190106A".  And the
"Fe II 1547.62, 1550.19, 2585.88, 2599.40, and Mg II doublet 2795.53, 2802.71" was changed to
"C IV 1547.62, 1550.19, Fe II 2585.88, 2599.40, and Mg II doublet 2795.53, 2802.71".]