Skip to main content
New SVOM Notices, Planned Retirement of VOEvent Brokers. See news and announcements

GCN Circular 26738

Subject
LIGO/Virgo S200114f: Coverage and upper limits from MAXI/GSC observations
Date
2020-01-14T04:34:49Z (5 years ago)
From
Hitoshi Negoro at Nihon U <negoro.hitoshi@nihon-u.ac.jp>
H. Negoro (Nihon U.), N. Kawai (Tokyo Tech), S. Sugita, M. Serino (AGU),
M. Nakajima, W. Maruyama, M. Aoki, K. Kobayashi, R. Takagi (Nihon U.),
T. Mihara, C. Guo, Y. Zhou, T. Tamagawa, M. Matsuoka (RIKEN),
T. Sakamoto, H. Nishida, A. Yoshida (AGU),
Y. Tsuboi, W. Iwakiri, R. Sasaki, H. Kawai, T. Sato (Chuo U.),
M. Shidatsu (Ehime U.), M. Oeda, K. Shiraishi (Tokyo Tech),
S. Nakahira, Y. Sugawara, S. Ueno, H. Tomida, M. Ishikawa, R. Shimomukai, M. Tominaga (JAXA),
Y. Ueda, A. Tanimoto, S. Yamada, S. Ogawa, K. Setoguchi, T. Yoshitake (Kyoto U.),
H. Tsunemi, T. Yoneyama, K. Asakura, S. Ide (Osaka U.),
M. Yamauchi, S. Iwahori, Y. Kurihara, K. Kurogi, K. Miike (Miyazaki U.),
T. Kawamuro (NAOJ), K. Yamaoka (Nagoya U.), Y. Kawakubo (LSU), M. Sugizaki (NAOC)
report on behalf of the MAXI team:

We examined MAXI/GSC all-sky X-ray images (2-20 keV)
after the LVC trigger S200114f at 2020-01-14 02:08:18.239 UTC (GCN 26734).

At the trigger time of S200114f, the high-voltage of MAXI/GSC was off,
and it was turned on at T0+653 sec (+10.9 min).
The first one-orbit (92 min) scan observation with GSC after the event covered 100%
of the 90% credible region of the cWB skymap from 03:09:02 to 03:29:47 UTC (T0+3644 to T0+4889 sec).

No significant new source was found in the region in the one-orbit scan observation.
A typical 1-sigma averaged upper limit obtained in one scan observation
is 20 mCrab at 2-20 keV.

If you require information about X-ray flux by MAXI/GSC at specific coordinates,
please contact the submitter of this circular by email.
Looking for U.S. government information and services? Visit USA.gov