Skip to main content
New! Browse Circulars by Event, Advanced Search, Sample Codes, Schema Release. See news and announcements

GCN Circular 2724

Subject
XRF 040912, identification of CXO sources
Date
2004-09-17T21:55:13Z (21 years ago)
Edited On
2024-11-18T10:07:10Z (7 months ago)
From
Alberto Castro-Tirado at Inst.de Astro. de Andalucia <ajct@iaa.es>
Edited By
Judith Racusin at NASA/GSFC <judith.racusin@nasa.gov> on behalf of Leo P. Singer at NASA/GSFC <leo.p.singer@nasa.gov>
J. Gorosabel (IAC-CSIC  Granada), J. Cepa (IAC 
Tenerife),  A. de Ugarte Postigo (IAA-CSIC), 
D. Martínez-Delgado (MPIfA Heidelberg),  V. Casanova, 
S. Guziy, M. Jelínek (IAA-CSIC, Granada), J. M. 
Castro Cerón (San Fernando), H. Castaneda (IAC 
Tenerife), D. Zucker, E. F. Bell (AIP Potsdam) 
and A. J. Castro-Tirado (IAA-CSIC)

report:

"We have acquired optical images covering the 
entire error box of the XRF 040912 detected by 
HETE-2 (Ricker et al. GCN Circ. 2701) starting
on 12 Sep 21:27 UT (i.e. 7.25 hr after the event). 
The  observations were performed with the 4.2m 
WHT (+PFC) at La Palma (16'x 16' FOV).

The observing log follows:

 -----------------------------------
 Date 2004 UT    Exp.Time (s)  Filter  
 -----------------------------------
 12 Sep 21:27:56      1455      B
 12 Sep 21:53:45       900      V
 13 Sep 04:26:41       900      V
 13 Sep 21:07:58      1200      V 
 16 Sep 01:49:11       300      I
 16 Sep 01:58:17       300      I
 16 Sep 02:05:06       300      I
 16 Sep 02:11:17       300      I
 16 Sep 02:18:16       300      I
 16 Sep 02:31:05       180      V
 16 Sep 02:35:14      1200      V
 ----------------------------------

Additional images (I-band, 720-s) were also 
taken at the 1.5m telescope at IAA Sierra 
Nevada Observatory on 13 Sep (03:00 UT). 

Internal comparison between the three V-band 
frames did not reveal any optical variable 
source in the entire HETE-2 error box. For 
the 22 X-rays sources detected by the Chandra 
X-ray Observatory (Butler et al., GCN Circ 
2716) we detect the following optical 
counterparts in the co-added V-band image 
(3 sigma limiting magnitude = 25.1):

 -------------------------------------
 CXO      V-band     Distance to
 source   magnitude  X-ray position (")
 -------------------------------------
   #1       21.6        2.0 
   #2       24.0        2.0 
   #3       21.1        2.0 
   #4       24.0        2.0 
   #5       21.9        1.4  
   #6       21.0        1.7 
   #7       22.9        1.7 
   #8       23.9        1.4 
   #9       23.9        1.8 
   #10      21.1        1.6 
   #11      23.0        1.4 
   #12      24.2        1.9 
   #13      23.6        0.5 
   #14*     23.9        0.9
            22.7        1.8 
   #15      23.9        2.1 
   #16**   >25.1         - 
   #17      24.5        2.0 
   #18      23.3        0.1 
   #19     >25.1         - 
   #20     >25.1         -        
   #21     >25.1         - 
   #22     >25.1         - 
 --------------------------------------
 * Two possible counterparts
 * V = 22.1 optical source at 3".5 
 --------------------------------------

Optical magnitudes are based on the calibration 
provided by A. Henden (GCN Circ. 2720)."

This message can be quoted.

[GCN OPS NOTE (21sep04): The affiliation for
D. Martinez-Delgado from "AIP Potsdam" to
"MPIfA Heidelberg".]
Looking for U.S. government information and services? Visit USA.gov