GCN Circular 43908
Subject
GRB 260303B: BALROG localization (Fermi Trigger 794237065 / GRB 260303559)
Event
Date
2026-03-03T14:05:07Z (a day ago)
From
Jochen Greiner at MPE <jcgrog@mpe.mpg.de>
Via
email
T. Preis (University of Innsbruck) & J. Greiner (MPE Garching) report:
The public trigdat data of the Fermi Gamma-ray Burst Monitor (GBM) trigger
794237065 at 13:24:20 on 03 March 2026 were automatically fitted for spectrum
and sky location with BALROG (Burgess et al. 2018, MNRAS 476, 1427;
Berlato et al. 2019, ApJ 873, 60).
The best-fit position is:
RA(2000.0) = 13.0 deg
Decl.(2000.0) = -27.8 deg
The 1 sigma statistical error radius is 1.3 deg.
We estimate an additional systematic error of 1 deg.
Further details are available at:
https://grb.mpe.mpg.de/grb/GRB260303559/
The Healpix map can be downloaded from:
https://grb.mpe.mpg.de/grb/GRB260303559/healpix
The location parameters are available as JSON at:
https://grb.mpe.mpg.de/grb/GRB260303559/json