GCN Circular 45880
Subject
EP261010a Einstein Probe detection of an X-ray transient
Event
Date
2026-10-10T01:35:27Z (3 days ago)
From
EP Team at NAOC/CAS <ep_ta@bao.ac.cn>
Via
Web form
A.Li (BNU), C.Y. Wang (THU), H.Z. Wu (HUST), C.L.Guo, H.Sun, (NAO, CAS), on behalf of the Einstein Probe (EP) team:
We report on the detection of an X-ray transient by the Wide-field X-ray Telescope (WXT) on board the Einstein Probe (EP) mission, designated EP261010a. The transient triggered EP-WXT (ID: 01709321061) at 2026-10-10T00:18:44 (UTC). The WXT position of the source is R.A. = 26.236 deg, DEC = -34.090 deg (J2000) with an uncertainty of 3 arcmin in radius (90% C.L. statistical and systematic).
A follow-up observation with the Follow-up X-ray Telescope (FXT) was performed automatically. Within the WXT error circle, an uncatalogued X-ray source was detected at R.A. = 26.2218 deg, DEC = -34.0893 deg (J2000) with an uncertainty of 20 arcsec in radius (90% C.L. statistical and systematic).
Further information will be updated when the telemetry data is received.
Launched on January 9, 2024, EP is a space X-ray observatory to monitor the soft X-ray sky with X-ray follow-up capability (Yuan et al. 2022, Handbook of X-ray and Gamma-ray Astrophysics).