Skip to main content
End of Swift Science Operations, CHIME Notices Unavailable During Upgrade. See news and announcements

GCN Circular 46371

Subject
GRB 261122B: SOAR optical detection at T0+3.2 days
Date
2026-11-26T08:17:32Z (a day ago)
From
Cheng Cheng at CAS South America Center for Astronomy (CASSACA) <chengcheng@nao.cas.cn>
Via
Web form
**AUTHORS:** Cheng Cheng (CASSACA, NAOC), Liping Xin (NAOC), Jia-Sheng Huang (CASSACA, NAOC) report:

We observed the field of GRB 261122B (SVOM/ECLAIRs, GCN 46336; refined analysis: Dinatolo et al., GCN 46365; SVOM/GRM: Luo et al., GCN 46369; optical counterpart: Wu et al., GCN 46338; Corcoran et al., GCN 46340; Yin et al., GCN 46341; Globus et al., GCN 46342; Li et al., GCN 46344; Hellot et al., GCN 46348; 5-GHz radio counterpart: Gulati et al., GCN 46351) with the 4.1-m SOAR telescope (Goodman High Throughput Spectrograph, red camera, imaging mode), under CNTAC proposal ID CN2026B-62 (PI: Jia-Sheng Huang).

Three 300-s exposures were obtained in each of the SDSS g, r, i and z filters starting at 2026-11-26 02:48:26 UT, i.e. T0 + 76.03 hr, where T0 = 2026-11-22 22:46:55 UT is the SVOM/ECLAIRs trigger time.  The observations were carried out at an airmass of 1.13-1.34, with the Moon 96% illuminated at an angular distance of 101 deg, and the FWHM of point sources in our stacked images is 1.7-2.0 arcsec.

The optical afterglow is detected at

  RA, Dec = 00:15:53.72, -38:49:41.6 (J2000) = 3.973846, -38.828221 (deg)

with an uncertainty of 0.2", which is 0.16" from the SVOM/VT position (Wu et al., GCN 46338).

The frames were processed from the raw data with bias and flat-field correction and background subtraction, the astrometry was solved for each frame, and the aligned frames were median-combined onto a common grid of 0.289 arcsec/pixel and about 4.8' x 4.8'.  Photometry was carried out in a 2.0-arcsec-diameter aperture, and the aperture flux was corrected to total flux using the point-source PSF measured from field stars on the same images.  The magnitudes are calibrated against Legacy Survey DR11 photometry of stars in the field, and we obtain

  Filter  T-T0 (hr)   mag (AB)
  g       76.15       22.80 +/- 0.54 (phot) +/- 0.07 (cal)
  r       76.79       22.49 +/- 0.23 (phot) +/- 0.02 (cal)
  i       76.47       22.74 +/- 0.40 (phot) +/- 0.02 (cal)
  z       77.14       21.93 +/- 0.27 (phot) +/- 0.02 (cal)

where the first uncertainty is the photometric error and the second is the calibration (zeropoint) uncertainty.  The calibration uncertainty is largest in the g band, where only a few bright stars are available.

As the source is faint, we only performed simple aperture photometry; a more careful measurement would require smoothing the images and a more refined treatment.  No colour term has been applied between the SOAR and Legacy Survey filter systems; a colour term of about 0.1 mag would be appropriate for a refined calibration.

A source is listed in Legacy Survey DR11 at 0.31" from the afterglow position (ls_id_dr11 = 48423010763281420), with g = 25.37 +/- 0.19, r = 25.52 +/- 0.32 and i = 25.00 +/- 0.29 (AB), and no z-band detection.

The quoted magnitudes are not corrected for Galactic extinction (E(B-V) = 0.017 along this line of sight).

We thank the SOAR staff for the rapid execution of these observations.

Looking for U.S. government information and services? Visit USA.gov