Skip to main content
Announcing GCN Classic Migration Survey, End of Legacy Circulars Email. See news and announcements

GCN Circular 8294

Subject
GRB 080928, Swift-BAT initial refined analysis
Date
2008-09-28T23:18:56Z (16 years ago)
From
Scott Barthelmy at NASA/GSFC <scott@lheamail.gsfc.nasa.gov>
J. Cummings (GSFC/UMBC), S. D. Barthelmy (GSFC), W. Baumgartner (GSFC/UMBC),
E. Fenimore (LANL), N. Gehrels (GSFC), C. Guidorzi (INAF-OAB),
H. Krimm (GSFC/USRA), C. Markwardt (GSFC/UMD), K. McLean (GSFC/UMD),
K. L. Page (U Leicester), D. Palmer (LANL), A. Parsons (GSFC),
T. Sakamoto (GSFC/UMBC), G. Sato (ISAS), M. Stamatikos (GSFC/ORAU),
J. Tueller (GSFC), T. Ukwatta (GWU)
(i.e. the Swift-BAT team):
 
Using the data set from T-239 to T+323 sec from recent telemetry downlinks,
we report further analysis of BAT GRB 080928 (trigger #326115)
(Sakamoto, et al., GCN Circ. 8292).  The BAT ground-calculated position is
RA, Dec = 95.063, -55.175 deg, which is 
   RA(J2000)  =  06h 20m 15.1s 
   Dec(J2000) = -55d 10' 29.5" 
with an uncertainty of 2.3 arcmin, (radius, sys+stat, 90% containment).
The partial coding was 84%.
 
The mask-weighted light curve shows that BAT triggered on a weak blip 
that occurred long before the main emission of this burst.  The initial
peak started at ~T-10 sec, peaked at ~T_zero, and returned to baseline
around T+30 sec.  Then a second, slightly larger peak, started at ~T+50
and ended at ~T+130 sec.  Then the main emission started at ~T+170, with
a pair of peaks at ~T+205 and ~T+215 sec.  We currently only have data
downlinked out to T+325 sec and the mask-weighted lightcurve shows
continued emission out to this time.  The flight-generated mask-weighted
lightcurve (lower resolution) shows no further peaks beyond T+325 sec.
The main peak at ~T+210 sec coincides with the peak emission in the
prompt XRT TDRSS lightcurve.
 
The time-averaged spectrum from T+51.1 to T+255.3 sec is best fit by a simple
power-law model.  The power law index of the time-averaged spectrum is
1.80 +- 0.12.  The fluence in the 15-150 keV band is 2.1 +- 0.1 x 10^-6 erg/cm2.
The 1-sec peak photon flux measured from T+202.83 sec in the 15-150 keV band
is 2.1 +- 0.1 ph/cm2/sec.  All the quoted errors are at the 90% confidence
level. 

When we get the remainder of the event-by-event data downlinked,
we will issue revised spectral fit results and a T90.
 
The results of the batgrbproduct analysis are available at
http://gcn.gsfc.nasa.gov/notices_s/326115/BA/
Looking for U.S. government information and services? Visit USA.gov