EP260110a
GCN Circular 43615
J. Sanchez-Sierras (Radboud), A. van Hoof (Radboud), P. G. Jonker (Radboud), D. Mata-Sanchez (IAC and ULL), A. J. Levan (Radboud), D. B. Malesani (DAWN/NBI and Radboud Univ.) report on behalf of a larger collaboration:
We observed the field of fast X-ray transient EP260110a (Zhang et al., GCNs 43363, 43367) with the Espectrógrafo Multiobjeto Infra-Rojo (EMIR) attached to the Gran Telescopio Canarias (GTC). The observations were performed in imaging mode and consisted of 260x5 s exposures, with a total exposure time of 1280 s in the H band, starting on 2026-02-01 at 06:08:10 UT (i.e. 21.76 days after the EP-WXT trigger).
We used this observation as a template to perform image subtraction from the GTC/EMIR image reported by Corcoran et al. (observed 19.02 hr after the trigger; GCN 43391), which had the same exposure time and instrument configuration. The subtraction was made using the ZOGY algorithm (Zackay et al. 2016), as implemented in PyZOGY (Guevel et al. 2021). No new sources are detected inside the EP-FXT error circle in the subtraction, down to the limit of the least deep image, i.e. upper limiting AB magnitude of H > 23.3 (calibrated using nearby stars from the 2MASS catalog).
GCN Circular 43391
G. Corcoran (UCD), P. G. Jonker (Radboud), J. Sanchez-Sierras (Radboud), A. Martin-Carrillo (UCD), J. A. Quirola-Vasquez (Radboud), A. van Hoof (Radboud), D. Mata Sanchez (IAC), D. Slumstrup (GTC), N. Castro Rodríguez (GTC), V. Vuolteenaho (NOT and Oulu Univ.) report on behalf of a larger collaboration:
We observed the field of the fast X-ray transient EP260110a (Zhang et al., GCNs 43363, 43367) using the Nordic Optical Telescope (NOT) equipped with the ALFOSC camera as well as in the near infrared with the Gran Telescopio Canarias (GTC) equipped with the EMIR instrument. Our observations consisted of two epochs of 3 x 300 s in SDSS-r band and 5 x 200 s in SDSS-z, taken from the NOT, and a single epoch in H with a total exposure time of 1280 s taken from the GTC.
Performing image subtraction with PyZOGY on our r-band stacked images and visually comparing the other bands to a stack of archival r-band CFHT images we do not detect any new sources within the EP/FXT uncertainty region in any of our images. We obtain the following upper limits:
| Mid time (UT) | Time since trigger (hr) | Band | 3 sigma UL (AB) |
|---|---|---|---|
| 2026-01-11 01:46:32 | 13.80 | r | 23.5 |
| 2026-01-11 02:04:27 | 14.10 | z | 22.3 |
| 2026-01-11 06:35:44 | 19.02 | H | 23.3 |
| 2026-01-12 03:03:04 | 39.08 | r | 24.2 |
| 2026-01-12 03:20:59 | 39.38 | z | 22.7 |
The r and z band upper limits were calibrated using nearby stars from the Pan-STARRS catalog while the 2MASS catalog was used for the H-band observations and the photometry is not corrected for Galactic extinction. Our upper limits are consistent with Perez-Garcia et al. (GCN 43364), Kang et al. (GCN 43365), Antier et al. (GCN 43366), Zheng et al. (GCN 43368), Lipunov et al. (GCN 43372), Li et al. (GCN 43375), and Zhu et al. (GCN 43390).
We note the presence of two faint sources within the EP/FXT uncertainty region in both our r- and H-band images, which are also seen in the archival CFHT imagery. While no residual is visible at their position in the r-band subtraction, due to the lack of sufficiently deep H-band templates we cannot test for NIR variability at this time.
GCN Circular 43390
Z.P. Zhu (NAOC), S. Tinyanont, K. Noysena, K. Chanchaiworawit(NARIT), J. An, X. Liu, S.Q. Jiang, L.B. He, N.C. Sun, W.X. Li, D. Xu (NAOC), S.Y. Fu (HUST) report on behalf of a large collaboration:
We observed the field of EP260110a detected by the Einstein Probe (EP) (Zhang et al., GCN 43363), using the 0.7-m telescope of the Thai Robotic Telescope network (TRT), located at Sierra Remote Observatories in California. We obtained several 360 s frames in the R filter. Observations started at 07:38:55 UTC on 2026-01-11, i.e., 0.44 day after the EP/WXT trigger time.
No new source is detected within or at the border of the EP/FXT error region (Zhang et al., GCN 43367), being consistent with the non-detection reported at other telescopes (Perez-Garcia et al., GCN 43364; Kang et al., GCN 43365; Antier et al., GCN 43366; Zheng et al., GCN 43368; Lipunov et al., GCN 43372; Li et al., GCN 43375). From the stacked images we obtain the following 5-sigma upper limits in Vega magnitude:
| Mid-time(d) | filter | upper limit | site |
|---|---|---|---|
| 0.46 | R | > 19.6 | SRO |
| 1.45 | R | > 20.9 | SRO |
| 2.44 | R | > 21.0 | SRO |
calibrated using nearby stars from the Pan-STARRS DR1 catalog and are not corrected for Galactic extinction.
GCN Circular 43375
H. L. Li, L. P. Xin, Y. L. Qiu, C. Wu, Y. N. Ma, Z. H. Yao, X. H. Han, J. Wang, P. P. Zhang, Y. Xu, W. J. Xie, Y. J. Xiao, H. B. Cai, L. Lan, J. R. Xu, J. S. Deng, J. Y. Wei (NAOC), J. Palmerio (CEA) report on behalf of the SVOM/VT team.
SVOM/VT performed ToO observation on the fast X-ray transient EP260110a (Zhang et al., GCN 43363; 43367). The observation started on 2026-01-10T14:29:11 UT (i.e. 2.52 hour post trigger) in VT_B (400nm-650nm) and VT_R (650nm-1000nm) channel simultaneously.
Inside the error box of the EP-FXT (Zhang et al., GCN 43367) we did not detect any new uncatalogued source, which was consistent with the non detections reported by other groups (Perez-Garcia et al., GCN 43364; Kang et al., GCN 43365; Antier et al., GCN 43366