EP260723a
GCN Circular 45227
Subject
EP260723a: SVOM/ECLAIRs Upper Limit
Date
2026-07-27T13:44:17Z (3 months ago)
From
SVOM_group <svomgroup@bao.ac.cn>
Via
Web form
H. Yang, M. Brunet, O. Godet, S. Guillot (IRAP)
report on behalf of the SVOM team:
We performed a targeted search of the X-ray transient EP260723a, detected by EP-WXT at 2026-07-23T18:56:01 UTC (T0) with a duration of about 100 s (EP team, GCN 45201), using the SVOM/ECLAIRs event-by-event data downloaded through the X-band ground station.
At T0, the transient position was within the ECLAIRs field of view. No statistically significant signal was identified in the [T0 - 500 s, T0 + 3000 s] interval by the ECLAIRs image trigger performed on multiple timescales and energy bands.
For the interval from T0 to T0 + 100 s, we derive a 3-sigma upper limit of 2.4e-9 erg/cm^2/s in the 4-120 keV energy band, assuming a power-law spectrum with a photon index of 1.4, as measured by EP-WXT (GCN 45201). Alternatively, assuming a “soft” spectral template (a Band function with Epeak = 25 keV, alpha = -1.5, beta = -3.0), we derive a 3-sigma upper limit of 1.5e-9 erg/cm^2/s.
The Space Variable Objects Monitor (SVOM) is a China-France joint mission led by the Chinese National Space Administration (CNSA), French Space Agency (CNES), and the Chinese Academy of Sciences (CAS), which is dedicated to observing gamma-ray bursts and other transient phenomena in the energetic universe. ECLAIRs was developed jointly by APC, CEA, CNES, and IRAP.
The SVOM/ECLAIRs point of contact for this event is : Hui Yang (hui.yang@cnrs.fr)
GCN Circular 45216
Subject
EP260723a: further EP-FXT follow-up observation
Date
2026-07-26T12:17:29Z (3 months ago)
From
EP Team at NAOC/CAS <ep_ta@bao.ac.cn>
Via
Web form
K. R. Ni (CCNU), Y. J. Zhang (PKU), X. H. Tang (THU), and H. Sun (NAOC) report on behalf of the Einstein Probe (EP) team:
EP-FXT performed a second follow-up observation of EP260723a, which was detected by EP-WXT (Zhang et al., GCN 45201) and previously followed up by EP-FXT (Ni et al., GCN 45209). The observation started at 2026-07-25T11:52:47 UTC, about 40.9 hr after the WXT detection, with an exposure time of approximately 6.0 ks. On-ground analysis of the FXT data identified an uncatalogued X-ray source within the WXT error circle at R.A. (J2000) = 2.9759 deg and Dec. (J2000) = -12.1022 deg, with an uncertainty of 10 arcsec in radius (90% confidence level, including both statistical and systematic uncertainties).
The source position is consistent with the optical counterpart reported by the Liverpool Telescope (Eyles-Ferris et al., GCN 45202, 45212), the Nordic Optical Telescope (He et al., GCN 45203), COLIBRÍ (Basa et al., GCN 45204), and SVOM/VT (Ma et al., GCN 45205), and also with the weak X-ray excess reported in the first EP-FXT follow-up observation (Ni et al., GCN 45209).
The average FXT spectrum in the 0.5-10 keV band can be fitted with an absorbed power-law model, with the hydrogen column density fixed at the Galactic value of 2.0 x 10^20 cm^-2 and a photon index of 2.96 (+1.53, -1.21). The derived average unabsorbed 0.5-10 keV flux is 3.1 (+3.0, -1.4) x 10^(-14) erg cm^-2 s^-1. The uncertainties quoted above are at the 90% confidence level.
Further EP-FXT follow-up observations will be arranged. Continued multi-band follow-up observations are encouraged.
Launched on January 9, 2024, EP is a space X-ray observatory designed to monitor the dynamic soft X-ray sky and perform follow-up observations of newly discovered transients (Yuan et al. 2022, Handbook of X-ray and Gamma-ray Astrophysics).
GCN Circular 45212
Subject
EP260723a: Continued Liverpool Telescope observations suggest hours long optical plateau or rebrightening
Date
2026-07-25T22:02:47Z (3 months ago)
From
Rob Eyles-Ferris at U of Leicester <raje1@leicester.ac.uk>
Via
Web form
R. A. J. Eyles-Ferris (Leicester) reports on behalf of a larger collaboration:
We observed the field of the Einstein Probe fast X-ray transient EP260723a (Zhang et al., GCN 45201; Ni et al. GCN 45209) with the 2m Liverpool Telescope on La Palma using the IO:O instrument. We obtained 12x150 s and 12x150 s exposures in each of the SDSS r’ and z’ filters starting at 2026-07-25 03:26:08 UT, approximately 32.5 hours after the X-ray detection.
We detect the optical counterpart (Eyles-Ferris et al., GCN 45202; He et al., GCN 45203; Basa et al., GCN 45204; Ma et al., GCN 45205) in both bands at AB magnitudes of r = 22.17 +/- 0.08 and z = 21.48 +/- 0.13. Our photometry is calibrated to PanSTARRS and not corrected for Galactic extinction.
We note that these magnitudes are consistent with those reported by Basa et al. (GCN 45204) approximately 19 hours earlier, suggesting an extended optical plateau or rebrightening. Further observations are planned.
GCN Circular 45209
Subject
EP260723a: EP-FXT follow-up observation
Date
2026-07-25T09:24:56Z (3 months ago)
From
EP Team at NAOC/CAS <ep_ta@bao.ac.cn>
Via
Web form
K. R. Ni (CCNU), Y. J. Zhang (PKU), X. H. Tang (THU), H. Sun (NAOC) on behalf of the Einstein Probe (EP) team:
EP-FXT performed a follow-up observation of EP260723a detected by EP-WXT (Zhang et al., GCN 45201). The observation started at 2026-07-24 08:44:22 UTC, about 13.8 hr after the WXT detection, with a total exposure time of around 3.0 ks.
On-ground analysis of the FXT data found no significant uncatalogued X-ray source in either the individual FXT-A or FXT-B image. After stacking the FXT-A and FXT-B data, a weak X-ray excess, with an S/N of approximately 2.2, was found at the position of the optical counterpart reported by the Nordic Optical Telescope (NOT; He et al., GCN 45203):
R.A. (J2000) = 2.97518 deg
Dec. (J2000) = −12.09851 deg
The optical counterpart was initially reported by the Liverpool Telescope (Eyles-Ferris et al., GCN 45202) and was subsequently confirmed by NOT (He et al., GCN 45203), COLIBRÍ (Basa et al., GCN 45204), and SVOM/VT (Ma et al., GCN 45205).
Given the low statistical significance, it is still unclear whether this weak X-ray excess is associated with EP260723a. The limited number of source counts does not allow meaningful spectral analysis.
Further EP-FXT follow-up observations will be arranged.
Launched on January 9, 2024, EP is a space X-ray observatory designed to monitor the dynamic soft X-ray sky and perform follow-up observations of newly discovered transients (Yuan et al. 2022, Handbook of X-ray and Gamma-ray Astrophysics).
GCN Circular 45205
Subject
EP260723a: SVOM/VT optical observation
Date
2026-07-24T12:08:26Z (3 months ago)
From
Yinuo Ma <mayn@bao.ac.cn>
Via
Web form
Y. N. Ma, L. P. Xin, H. L. Li, Y. L. Qiu, C. Wu, Z. H. Yao, J. R. Xu, X. H. Han, Y. Xu, J. Wang, P. P. Zhang, W. J. Xie, Y. J. Xiao, H. B. Cai, J. S. Deng, J. Y. Wei (NAOC), J. Palmerio (CEA) report on behalf of the SVOM/VT team.
SVOM/VT performed a Target of Opportunity observation of EP260723a detected by EP/WXT (Zhang et al., GCN 45201). SVOM/VT began observing the field at 2026-07-24T05:35:28 UTC, 10.658 hours after the trigger, in the VT_B (400nm-650nm) and VT_R (650nm-1000nm) channels simultaneously.
With X-band data available, the optical counterpart (Eyles-Ferris et al., GCN 45202