Skip to main content
Retirement of GCN Classic VOEvent Brokers. See news and announcements

GRB 190324B, GRB 190324

GCN Circular 24012

Subject
GRB 190324B: Insight-HXMT/HE detection
Date
2019-03-26T13:38:15Z (7 years ago)
From
Qi Luo at IHEP <luoqi@ihep.ac.cn>
Q. Luo, C. K. Li, X. B. Li, G. Li, J. Y. Liao, S. L. Xiong, 
C. Z. Liu, X. F. Li, Z. W. Li, Z. Chang, X. F. Lu,
A. M. Zhang, Y. F. Zhang, C. L. Zou (IHEP), Y. J. Jin, 
Z. Zhang (THU), T. P. Li (IHEP/THU), F. J. Lu, L. M. Song, 
M. Wu, Y. P. Xu, S. N. Zhang (IHEP),
report on behalf of the Insight-HXMT team:

At 2019-03-24T08:21:21.000 (T0), the Insight-HXMT/HE detected
GRB 190324B(trigger ID: HEB190324348) in a routine search of the data,
which was also triggered by Fermi/GBM(J. Burgess et al. ,GCN 23992).

The Insight-HXMT/HE light curve consists of multiple 
pulses with a duration (T90) of 46.07 s measured from T0+1.05 s.
The 1-ms peak rate, measured from T0+1.952 s, is 2937 cnts/sec.
The total counts from this burst is 30168 counts.
URL_LC: http://www.hxmt.org/images/GRB/HEB190324348_lc.jpg

All measurements above are made with the CsI detectors operating in the
regular mode with the energy range of about 80-800 keV (record energy).
Only gamma-rays with energy greater than about 200 keV can penetrate
the spacecraft and leave signals in the CsI detectors installed inside
of the telescope.

Insight-HXMT is the first Chinese space X-ray telescope, which was
fundedjointly by the China National Space Administration (CNSA) and
the Chinese Academy of Sciences (CAS).
More information about it could be found at:
http://www.hxmt.org.

GCN Circular 23992

Subject
Fermi Trigger 575108474 / GRB 190324348: BALROG localization
Date
2019-03-24T08:43:38Z (7 years ago)
From
Jochen Greiner at MPE,Garching <jcg@mpe.mpg.de>
J. Burgess , F. Kunzweiler, B. Biltzinger, F. Berlato & J. Greiner (all MPE Garching) report:

The public trigdat data of the Fermi Gamma-ray Burst Monitor (GBM) trigger
575108474 at 08:21:09 on 24 March 2019 were automatically fitted for spectrum
and sky location with BALROG (Burgess et al. 2018, MNRAS 476, 1427;
Berlato et al. 2019, ApJ 873, 60).

The best-fit position (1 sigma statistical errors) is:
RA(2000.0) = 80.4+/-1.1 deg
Decl.(2000.0) = 10.2+/-1.1 deg
We estimate an additional systematic error of 2 deg.

Further details are available at:
https://grb.mpe.mpg.de/grb/GRB190324348/

The Healpix map can be downloaded from:
https://grb.mpe.mpg.de/grb/GRB190324348/healpix

The location parameters are available as JSON at:
https://grb.mpe.mpg.de/grb/GRB190324348/json

Looking for U.S. government information and services? Visit USA.gov