GRB 260307B
GCN Circular 44133
Subject
GRB 260307B: ATCA Radio Upper Limits
Date
2026-03-27T18:33:22Z (7 months ago)
From
Sarah Chastain at Texas Tech University <sarahichastain@gmail.com>
Via
Web form
S. I. Chastain (TTU), G. E. Anderson (CSIRO), S. Ryder (Macquarie), A. Gulati (USyd), A. J. van der Horst (GWU), J. K. Leung (UofT/HUJI), and L. Rhodes (TSI/McGill) on behalf of the ATCA PanRadio GRB collaboration:
We observed the long GRB 260307B detected by SVOM (SVOM Team, GCN 43940) with the Australia Telescope Compact Array (ATCA) 0.9, 4.8, and 11 days post-burst.
No radio source was detected within the SVOM MXT localization (SVOM Team, GRB43940). At 8 GHz we find 3-sigma upper limits of 36, 33, and 30 microJy/beam, at 0.9, 4.8, and 11 days post-burst respectively.
We thank the CSIRO Space and Astronomy staff for supporting these observations.
We acknowledge the Gomeroi people as the traditional owners of the Observatory site. The Australia Telescope Compact Array is part of the Australia Telescope National Facility (https://ror.org/05qajvd42) which is funded by the Australian Government for operation as a National Facility managed by CSIRO.
GCN Circular 43953
Subject
GRB 260307B: SVOM/ECLAIRs refined analysis
Date
2026-03-10T16:09:19Z (8 months ago)
From
SVOM_group <svomgroup@bao.ac.cn>
Via
Web form
M. Brunet, L. Bouchet (IRAP), F. Magnani, A. Foisseau (CPPM), report on behalf of the SVOM/ECLAIRs team.
Using the event-by-event data downloaded through the X-band ground station, we report further analysis of SVOM/ECLAIRs observations of GRB 260307B (SVOM burst-id sb26030704 – GCN 43940, trigger time T0 = 2026-03-07T13:45:26 UTC), which was also detected by Fermi/GBM (GCN 43948).
The burst that triggered ECLAIRs shows a single peak lightcurve lasting for around 41 s prior to the slew, followed by a featureless emission after the slew. The burst duration is estimated to be around 580 s in the 4-120 keV energy band through imaging.
The time-averaged spectrum before the slew (from T0-24 s to T0+17 s) in the energy range 5-120 keV is best fitted by a powerlaw model with a photon index of -1.29 +/-0.10. With this model, the 4-120 keV fluence is (9.4 +0.5/-1.4)e-7 erg/cm^2 and the 4-120 keV photon flux is 0.54 +0.02/-0.06 ph/cm^2/s.
The time-averaged spectrum after the slew (from T0+151 s to T0+560 s) in the energy range 5-120 keV is best fitted by a powerlaw model with an exponential cutoff. The photon index is -0.96 +0.37/-0.33 and the peak energy is 36 +38/-14 keV. With this model, the 4-120 keV fluence is (1.4 +0.1/-0.7)e-6 erg/cm^2 and the 4-120 keV photon flux is 0.12 +0.01/-0.06 ph/cm^2/s.
Using the best fit parameter from the spectrum before the slew to fit the spectrum after the slew does not give a good fit (chi²/dof: 21.1/12), which implies the presence of a spectral evolution with time.
All the quoted errors are at the 68% confidence level.
The Space-based multi-band astronomical Variable Objects Monitor (SVOM) is a China-France joint mission led by the Chinese National Space Administration (CNSA), French Space Agency (CNES), and the Chinese Academy of Sciences (CAS), which is dedicated to observing gamma-ray bursts and other transient phenomena in the energetic universe. ECLAIRs was developed jointly by CNES, CEA-IRFU, CNRS-IRAP, CNRS-APC.
The SVOM/ECLAIRs point of contact for this burst is: Marius Brunet (IRAP) (marius.brunet at utoulouse.fr)
GCN Circular 43948
Subject
Fermi GBM Sub-Threshold Detection of GRB 260307B
Date
2026-03-08T15:14:09Z (8 months ago)
From
Rushikesh Sonawane at IISER, TVM <rushikesh23@iisertvm.ac.in>
Via
Web form
R. Sonawane (IISER TVM), reports on behalf of the Fermi-GBM Team:
SVOM/ECLAIRs detected the GRB 260307B on 2026-03-07 at 13:45:26 UTC (Magnani et al. 2026, GCN 43940). There was no Fermi-GBM onboard trigger around this event time. An automated, blind search for gamma-ray bursts below the onboard triggering threshold in Fermi-GBM identified a candidate.
The GBM Targeted Search [1], the most sensitive coherent search for GRB-like signals in GBM, identified a transient starting at 2026-03-07T13:45:30.6 (UTC), most significantly on the 32 s timescale, with a false alarm rate of 2.5e-04 Hz. The Fermi-MET of this transient is 794583935.8 s. The Targeted Search localization is found to be spatially consistent with the SVOM/ECLAIRs localization.
Additionally, the GBM Targeted Search event was found with the highest significance using a
"soft" spectrum (Band function with Epeak = 70 keV, alpha = -1.9, beta = -3.7) for a GRB.
[1] Goldstein et al. 2019 arXiv:1903.12597
GCN Circular 43947
Subject
GRB 260307B: Mephisto optical upper limits
Date
2026-03-08T13:15:21Z (8 months ago)
From
Brajesh Kumar at SWIFAR, YNU <brajesh@ynu.edu.cn>
Via
Web form
Guowang Du, Weikang Lin, Xueling Du, Donglin Gao, Xueteng Zhang, Yu Pan, Xingzhu Zou, Xinlei Chen, Brajesh Kumar, Yuan Fang, Jinghua Zhang, Xufeng Zhu, Tao Wang, Xinzhong Er, Yuanpei Yang, Xiangkun Liu, Xiaowei Liu (SWIFAR, YNU) report on behalf of the Mephisto Team:
The 1.6m Multi-channel Photometric Survey Telescope (Mephisto) of Yunnan University, located at the Lijiang Observatory, was triggered at 2026-03-07T13:48:27 (~181 seconds after the SVOM/ECLAIRs trigger) to observe the field of SVOM GRB 260307B (Magnani et al., GCN 43940). A set of simultaneous multi-band (ugi and vrz) images was collected. In our stacked frames, no optical candidate was detected within the SVOM/ECLAIRs localization and at the position reported by Corcoran et al. (GCN 43946